BELL-HOUSINGS & COUPLINGS SIZING
A GUIDE TO SELECT THE CORRECT BELL-HOUSING AND DRIVE COUPLING MANUALLY
Pages 75 ÷ 81 for IEC Electric motor size 100-112 - LMC250
LMC 250 bell-housing with height ≥ 135.5 - LMC250AFSQ
The bell-housing code must be completed with pump drilling code (see pages 60-61).
For the specic case:
Spigot hole 82.55 - PCD 106.4 - Nr.2 holes M10 : Drilling code 060
Denitive bell-housing code LMC250AFSQ060
Pages 83 ÷ 89 for IEC Electric motor size 100-112 - LMS250
LMS 250 bell-housing with height ≥ 135.5 - LMS250AFSA
The bell-housing code must be completed with pump drilling code (see pages 60-61).
For the specic case:
Spigot hole 82.55 - PCD 106.4 - Nr.2 holes M10 : Drilling code 060
Denitive bell-housing code LMS250AFSA060
Bell-Housing’s length calculation
Case A
Solution with monobloc bell-housing series LMC/LDC
Case B
Solution with low noise bell-housing series LMS/LDS
- H = 60 + 18 + 57.5 = 135.5 mm (18 = Sp spider - see page 31)
- Choose type of bell-housing (LMC - LMS):
For monobloc bell-housing LMC/LDC series see pages 75 ÷ 81
For Low noise bell-housing LMS/LDS series see pages 81 ÷ 89
For Multi-components 2-3 bell housing series see pages 91 ÷ 111
Note:
The length of bell-housing must be ≥ than the length calculated (135.5 mm)
- Electric motor power/motor size
- Manufacturer and pump type
1 - Pump and motor shaft dimensions (see electric motor data sheet)
2 - Shaft and ange pump (see pump data sheet)
Example:
- Electric motor 2.2 kW - size 100-112
- Atos pump code PFE31 - Shaft 1
DATA REQUIRED
TO VERIFY:
IEC Electric motor dimension Hydraulic pump dimension
Ø28 - key 8
Ø19.05 - key 4.76
Ø250
60
57.5
9.5
Ø82.55
Ø106.4
Nr. 2 Ø11
code M05 see page 18
code G01 see page 18
Introduction
12